Overview

Roof Safety Systems Melbourne
Roof Safety Systems Melbourne
Roof Safety Systems Melbourne

SL2

The SL2 concrete mount static line is a proprietary fall arrest system suitable for multiple users, providing a high level of safety for workmen and maintenance personnel requiring safe access to plant and equipment. The system offers continuous attachment and incorporates low profile, high quality components which can be used in horizontal, vertical and overhead applications using the required system traveller.

  • Fall arrest use
  • 22kN rated
  • Multi user capability
  • Advanced energy absorbing technology
  • Smooth intermediate pass-through system
  • Simple installation using modular components
  • Low profile system with powder coating option

Specification

Materials

Stainless steel profiled plate assembly including end stanchions, intermediates, corners, cable and connection devices.

Dimensions

  • Attachment cable: 8mm (7 x 7 strand)
  • Cable height off structure: 125mm to 150mm

Fixings

  • Metal fixing: M14 stainless steel stud fixing
  • Concrete fixing: M12 mechanical concrete anchor
  • Metal roof deck fixing: 8mm construction grade bulb type rivets

Substructure requirements

  • Maximum roof pitch: 30 degrees across slope, 15 degrees with slope
  • Support structure integrity, suitability and fixing method to be assessed and determined by a competent person prior to installation.

Rating

  • Rated 22kN for fall arrest use
  • User weight limit: 120kg (user and equipment)
  • Up to 4 users per line, determined by intermediate spacing and roof pitch

Compliance

All Safe Height Safety Solutions static lines are designed to conform to requirements of Australian & New Zealand Standards AS/NZS 5532:2013, AS/NZS ISO 22846, AS/NZS 1891.4.2009 and relevant statutory codes of practice and guidelines.

Testing

Testing and performance based on requirements of Australian & New Zealand Standard AS/NZS 1891 and AS/NZS 5532.

Key features

1. End stanchion

Provides a secure termination anchorage for the cable.

2. Cable tensioner with indicator

Ensures line tension can be adjusted after installation and during maintenance

3. Intermediate

To support the cable and reduce forces on the stanchions.

4. Corner

Supports a change in the direction of the cable.

5. Traveller

Providing smooth operation along the cable for the operator, and the fail safe cable locking feature on this unit ensures total user confidence when attached to the system.

6. Energy absorber

Designed to deploy under excessive load, limiting forces on the system and operator.

Roof Safety Systems Melbourne

Get a Quote From a Certified Installer You Can Trust

Contact our experts — Melbourne specialists delivering fast, reliable and cost-effective height safety solutions.


    Scroll to top